InterOcean logo InterOcean systems, inc.
Home Products Technical Support Customer Service Company Profile Contact Us Company News Sitemap

Software and Accessories

Software


S4 Application Software For Windows  New!

Current Version: 3.0.4

Next-Generation Software for InterOcean Family of S4 Current Meters and Oceanographic Instruments.

Product Description

(compatible with Windows versions 95, 98, NT, 2000, and XP).



Wave for Windows

Current Version: 3.0

Description:
Ocean Wave analysis and display program for complete statistical description and reporting of the wave climate at a specific location using the time series pressure and velocity vector data collected by an S4DW or S4ADW directional wave instrument. Fast Fourier Transform (FFT) techniques convert from time series into frequency spectra for detailed wave energy analysis. Data is presented in tabular and graphical format allowing full user selection of presentation format. The same software may be used for unidirectional wave analysis of data collected from a WTG/S4, WTG904 series 3 or series 4 instruments. Upgrade from Version 2.2 to 3.0 allows processing of large 256 MB data file from S4ADW.

Sample Screenshot 1 – 2D Graph

Sample Screenshot 2 – 3D Graph



S4 Telemetry Software

Current Versions: 2.7

Description:
Allows connection to remote instruments via direct cable, wire modem, RF modem, or satellite link. The software acquires, processes, displays and stores all oceanographic, meteorological, and directional wave data from an S4 and optional meteorological instruments in real-time.

The software is designed to run on any PC (win2000, XP) using the Microsoft Windows 95/98 or Windows NT operating systems. Menu-based setup screens are incorporated to provide easy setup of logging parameters using point-and-click commands. Standard Windows drop-down menus are used to configure communication ports, calibration settings, file and printer options. Complete communications port status monitoring and display is included. Collected and processed data may be printed and/or sent to remote computers via a second serial port. Remote control software may be used to access the data files, and monitor and control the process from a remote computer.

Version 2.7 allows increased flexibility in the selection and configuration of special sensor options, and incorporates automatic high frequency selection for real-time wave analysis using a dynamic pressure response factor appropriate to the installed depth.

Sample Screenshot

For alternate software used with InterOcean real-time Telemetry Applications, see the Environmental Monitoring Systems Example page.



S4 Web Telemetry Application Software

Description:
Provides for Worldwide distribution of Real-Time Hydrographic Data over the Internet, allowing the user to avoid costly satellite usage. The user defines the hydrographic parameters to be displayed. Password protection is available. Applications include distribution of data for Scientific Research, Vessel Traffic Systems, Harbor/Navigation Monitoring, Offshore Platforms and Terminals. This software module links any of the above applications with the World Wide Web.

Sample Screenshot


Accessories

S110A Interface Unit

The S110A provides three basic functions:
  1. Easy interconnection between S4 and computer: RS232 Input/Output cables are provided for between the S110A and PC computer, and between the S4 and S110A. Extension cables can be provided in any length between the S4 and S110A Interface for real-time applications over long cables.
  2. External power to the S4: The S110A can provide surface power for permanent real-time operations, or provide power for data recovery communications when S4 battery power is low.
  3. Line Drivers: The S110A provides optical isolation and communication with the S4 over long cables greater than one kilometer in length. The S110A supports baud rates up to and including 57,600 baud when used with the S4A Current Meter and baud rates to 19,200 with the standard S4 Current meter. Communication speed may depend on cable length.


S110M Interface Unit

Provides the interface between a modem and an InterOcean Model S4 or S4A Current Meter. The S110M accepts RS232 input and formats the data to signal levels compatible with the S4(A) Current Meter, and also provides optical isolation and line drivers for the output data to the S4(A).

The S110M series was developed for applications where a manual turn-on command cannot be provided over a wireless link. The S110M monitors the input data on the RS232 line, and when a specific data string is detected a turn-on signal is generated and sent to the S4(A) instrument. Following turn-on, communication with the S4(A) is identical to a standard S110A Interface to the current meter. The special turn-on command string is automatically generated by the InterOcean Software for modem applications using the S110M Interface.



S110A08 Interface Unit

Remote Digital to Analog converter for the S4 Current Meter. The unit converts the serial RS232 data stream from the S4 Current Meter into two (or more) 0-5 Volt analog outputs. The S110A08 includes standard voltage outputs for both Current Speed and Direction. Additional outputs for Conductivity, Temperature, Depth, and Tilt are available as options. The S110A08 is housed in a rugged polycarbonate enclosure and is powered by +12 VDC and/or 115 VAC (220 VAC units are available).


S110A08mA Interface Unit

Remote Digital to 4-20 mA Analog converter for the S4 Current Meter. The unit converts the serial RS232 data stream from the S4 Current Meter into two (or more) analog outputs. The S110A08 includes standard 4-20 mA outputs for both Current Speed and Direction. Additional outputs for Conductivity, Temperature, Depth and Tilt are available as options. The S110A08mA is housed in a rugged fiberglas enclosure and is powered by 115 VAC and 24 VDC Current Loop voltage.


BATTERY PACK, Model ExBP

Model ExBP External Battery Pack for the S4 Series of Instruments. Allows long-duration, self-contained autonomy for continuous high-density burst sampling. Typically used with the S4A 256 Megabyte memory option.

90 amp-hour rating. Contains 42 alkaline D cells. Includes cable for connection to any S4 instrument.